BROADSHIELD® MCS-EA
MODULAR COUNTERMEASURES SUITE FOR ELECTRONIC ATTACK
KEY FEATURES
-
Multi-platform EA
-
Modes include: Constant Jamming, Re-Active Jamming, Deception and Emulation
-
20MHz to 6GHz Spectral Coverage
-
Integral receiver for re-active communications jamming
-
2 x 10W RF output power (1Kw external PA option for vehicles)
-
Fully Ruggedised MOTS solution
-
Compatible with L-3 TRL’s IEW capability
-
Scalable dual-use capability in EA & FP modes
-
Comprehensive range of Training and Support packages
BROADSHIELD MCS-EA IS A COMPACT, PROGRAMMABLE AND MODULAR CONTERMEASURES SUITE FOR ELECTRONIC ATTACT (EA) SUITABLE FOR MOUNTING ON A RANGE OF LAND AND MARITIME PLATFORMS AS AN INTEGRAL PART OF AN INTEGRATED ELECTRONIC WARFARE (IEW) SOLUTION.
Built on L-3 TRL’s latest Advanced Processor Board technology MCS-EA utilises 2 units to cover the complete 20Mhz to 6Ghz
threat spectrum. The unit contains an integral receiver, allowing it to scan target frequencies up to 3GHz. Complex deception can be achieved for use on operations or as part of a simulated training environment. EA can be conducted from a standalone system, or as part of a networked, coordinated attack, utilising up to 64 MCS-EA units at any given time.
The BROADSHIELD MCS-EA unit has an intuitive Graphical User Interface (GUI), enabling basic or advanced jamming techniques to be programmed and transmitted. It can be reprogrammed in the field using its dedicated EA GUI to configure modulation techniques, waveforms, target frequencies and operating parameters. Settings are stored in a non-volatile memory to be activated in response to a signal of interest, a preset time schedule or across a command and control network, such as L-3 TRL's Tactical Integrated EW (IEW) capability.
BROADSHIELD MCS-EA offers true dual-use capability, with a simple firmware change enabling the operator to switch from Force Protection to Electronic Attack mode. When mounted with the HCS-EA unit, the system can allow use of either dedicated 50W power amplifiers or supplementary 1kW options. In vehicle mode it offers a powerful communications denial tool for conventional EW operations.
L-3 TRL offers a proven support model for all of our systems. This includes specialist training for operator, trainer and programmer, a central support desk function and a dedicated threat cell offering device exploitation and waveform creation.
TECHNICAL SPECIFICATIONS
PHYSICAL CHARACTERISTICS
Dimensions:
(Excluding battery and antennas) H 282mm x W 229mm x D 90mm
Weight:
4.5kg - 5kg (excluding battery and antennas)*
8kg - 9kg (including battery and antennas)*
*Dependant on chassis material and battery / antenna choice
Power Consumption:
Low band: <80W typ
High band: <140W typ
Power Supply:
Battery operated (2x BB-2590 or equivalent, LIPS 5)
Operating Limits:
19-33V DC
Temperature Range:
Operating: -40 ̊C to +60 ̊C
Storage: -40 ̊C to +85 ̊C
Chassis Material:
Machine aluminium allow chassis with integral forced air cooling
Carbon Fibre variant also available
Finish:
Powder Coat. Standard colour options:
- Jet Black (RAL 9005)
- Grey Beige (RAL 1019)
- NATO Green/IRR (BS381C 285)
- Pebble Grey (RAL 7032)
Transmitter:
20MHz to 1GHz
420MHz to 6GHz
Receiver:
22MHz to 1GHz
420MHz to 3 GHz
Power Inputs:
LIPS battery or external battery compartment, compatible with BB- 2590 or equivalent military primary or secondary battery packs (e.g. BB-390, BB-590, BB-5590, BA-5390)
RF Ports:
2 x N-type 50Ω Tx ports
User Interface:
Front panel membrane keypad
RS232 115.2k Baud
USB
Both via front panel circular connector
Synchronisation:
Can be synchronised by internal or external source
Alarms:
Alarm indicators on front panel
Audible alarm built into main unit
Visible/audible alarms for unit diagnostics
Programming Methods:
Windows-based BROADSHIELD MCS-EA software
Zeroize sequence initiated via front panel data connector. Erases all mission data, synchronisation and operating firmware.
Signal Generation Method
Direct Digital Synthesis (DDS)
Please refer to L-3 TRL for further detail*
Handling/Transit:
Compliant with the following MIL-STD 810F standards:
Method, procedure:
Vibration (transport) 514.5, 1
Transit drop 516.5, 4
Environmental:
Compliant with the following MIL-STD 810F standards:
Method, procedure:
Low pressure survival 500.4, 1
Low temperature storage (-40 ̊C) 502.4, 1
Low temperature operation (-40 ̊C) 502.4, 2
High temperature storage (+85 ̊C) 501.4, 1
High temperature operation (+55 ̊C) 501.4, 2
High humidity 507.4, 1
Blowing rain 506.4, 1
Blowing dust 510.4, 1
Blowing sand 510.4, 2
Electromagnetic Compatibility (EMC):
Compliant with the following MIL-STD 461E standards:
Test:
Conducted susceptibility
CS114, CS115, CS116
Radiated susceptibility RS103
Radiated emissions RE102
Electrostatic Discharge (ESD):
ESD Immunity compliant with BS EN61000-4-2
Transmitter:
20MHz to 1GHz
420MHz to 6GHz
Receiver:
22MHz to 1GHz
420MHz to 3 GHz
Power Inputs:
LIPS battery or external battery compartment, compatible with BB- 2590 or equivalent military primary or secondary battery packs (e.g. BB-390, BB-590, BB-5590, BA-5390)
RF Ports:
2 x N-type 50Ω Tx ports
User Interface:
Front panel membrane keypad
RS232 115.2k Baud
USB
Both via front panel circular connector
Synchronisation:
Can be synchronised by internal or external source
Alarms:
Alarm indicators on front panel
Audible alarm built into main unit
Visible/audible alarms for unit diagnostics
Programming Methods:
Windows-based BROADSHIELD MCS-EA software
Zeroize sequence initiated via front panel data connector. Erases all mission data, synchronisation and operating firmware.
Signal Generation Method
Direct Digital Synthesis (DDS)
Please refer to L-3 TRL for further detail*
Handling/Transit:
Compliant with the following MIL-STD 810F standards:
Method, procedure:
Vibration (transport) 514.5, 1
Transit drop 516.5, 4
Environmental:
Compliant with the following MIL-STD 810F standards:
Method, procedure:
Low pressure survival 500.4, 1
Low temperature storage (-40 ̊C) 502.4, 1
Low temperature operation (-40 ̊C) 502.4, 2
High temperature storage (+85 ̊C) 501.4, 1
High temperature operation (+55 ̊C) 501.4, 2
High humidity 507.4, 1
Blowing rain 506.4, 1
Blowing dust 510.4, 1
Blowing sand 510.4, 2
Electromagnetic Compatibility (EMC):
Compliant with the following MIL-STD 461E standards:
Test:
Conducted susceptibility
CS114, CS115, CS116
Radiated susceptibility RS103
Radiated emissions RE102
Electrostatic Discharge (ESD):
ESD Immunity compliant with BS EN61000-4-2